一、如遇外电来电后瓦斯发电机不能自动停机操作:
1、 If the gas generator can not automatically stop operation after external power supply:
1. 手动停机,直接将转换开关由3点方向转至12点方向,这是发电机停机;
1. Manual shutdown, directly turn the universal change-over switch from 3:00 to 12:00, which is the generator shutdown;
2. 打开2#低压配电柜,上方开关为动力开关,下方为照明开关,在照明开关左边有一小三角论,请操作人员员戴上绝缘手套,向上转动三角轮,待听到响声后即已经合闸送电;
2. Turn on the 2 ා low voltage distribution cabinet. The upper switch is the power switch, and the lower part is the lighting switch. There is a small triangle on the left side of the lighting switch. Please put on insulating gloves and turn the triangle wheel upward. After hearing the noise, the power supply has been switched on;
3. 关闭柜门,将发电机由手动状态转至自动状态,恢复生产。
3. Close the cabinet door, turn the generator from manual state to automatic state and resume production.
二、如遇接到停电通知时,请提前测试瓦斯发电机运行状态,确保停电时正常运行!启机步骤如下:
2、 In case of power failure notice, please test the operation status of gas generator one day in advance to ensure normal operation during power failure. The starting steps are as follows:
瓦斯发电机组
1. 检查瓦斯气压力、润滑油油位、两水箱的冷却液液位,
1. Check gas pressure, lubricating oil level and coolant level of two water tanks,
2. 将发电机有自动状态转换至手动状态;将转换开关由3点方向左旋转至12点方向为手动状态;
2. Switch the generator from automatic state to manual state; rotate the universal transfer switch from 3-point direction to 12:00 direction to manual state;
3. 断开左下方发电机断路器;将断路器手柄扳至下方极为断开;
3. Disconnect the generator circuit breaker at the lower left; pull the handle of the circuit breaker to the lower pole to disconnect it;
4. 启动发电机;将转换开关由12点方向向左旋转至6点方向即为点火启动机器;
4. Start the generator; turn the universal change-over switch from 12:00 to 6:00 to start the machine;
5. 机器启动运行后请仔细关注电压400V,频率50HZ,转速1500转,运行10分钟待水温上升至60℃时,将转换开关由6点方向旋转至9点方向即为待机运行状态,5分钟后机器会自动停机;
5. After the machine is started, please pay attention to the voltage of 400V, frequency of 50Hz, speed of 1500 rpm, and run for 10 minutes. When the water temperature rises to 60 ℃, turn the universal change-over switch from 6 o'clock to 9:00 o'clock, which is the standby operation mode. After 5 minutes, the machine will stop automatically;
6. 测试结束后,请回复断路器合闸状态,将转换开关由9点方向旋转至3点方向,待停电时会自动启机。
6. After the test, please return to the closing state of the circuit breaker, turn the universal transfer switch from 9:00 to 3:00, and the machine will start automatically when the power is cut off.
上面的内容就是今天小编给大家介绍的内容了,我们真诚为您提供瓦斯发电机组服务,您的满意就是我们的责任,欢迎在网站下方留言:http://www.huannengpower.com
The above content is the content introduced to you today. We sincerely provide you with gas generator set service, and your satisfaction is our responsibility. Welcome to leave a message at the bottom of the website: http://www.huannengpower.com
新闻搜索
济南济柴环能燃气发电设备有限公司
  • 服务热线

    0531-62325028
    0531-69951266

瓦斯发电机组遇到故障怎么解决才好?

一、如遇外电来电后瓦斯发电机不能自动停机操作:
1、 If the gas generator can not automatically stop operation after external power supply:
1. 手动停机,直接将转换开关由3点方向转至12点方向,这是发电机停机;
1. Manual shutdown, directly turn the universal change-over switch from 3:00 to 12:00, which is the generator shutdown;
2. 打开2#低压配电柜,上方开关为动力开关,下方为照明开关,在照明开关左边有一小三角论,请操作人员员戴上绝缘手套,向上转动三角轮,待听到响声后即已经合闸送电;
2. Turn on the 2 ා low voltage distribution cabinet. The upper switch is the power switch, and the lower part is the lighting switch. There is a small triangle on the left side of the lighting switch. Please put on insulating gloves and turn the triangle wheel upward. After hearing the noise, the power supply has been switched on;
3. 关闭柜门,将发电机由手动状态转至自动状态,恢复生产。
3. Close the cabinet door, turn the generator from manual state to automatic state and resume production.
二、如遇接到停电通知时,请提前测试瓦斯发电机运行状态,确保停电时正常运行!启机步骤如下:
2、 In case of power failure notice, please test the operation status of gas generator one day in advance to ensure normal operation during power failure. The starting steps are as follows:
瓦斯发电机组
1. 检查瓦斯气压力、润滑油油位、两水箱的冷却液液位,
1. Check gas pressure, lubricating oil level and coolant level of two water tanks,
2. 将发电机有自动状态转换至手动状态;将转换开关由3点方向左旋转至12点方向为手动状态;
2. Switch the generator from automatic state to manual state; rotate the universal transfer switch from 3-point direction to 12:00 direction to manual state;
3. 断开左下方发电机断路器;将断路器手柄扳至下方极为断开;
3. Disconnect the generator circuit breaker at the lower left; pull the handle of the circuit breaker to the lower pole to disconnect it;
4. 启动发电机;将转换开关由12点方向向左旋转至6点方向即为点火启动机器;
4. Start the generator; turn the universal change-over switch from 12:00 to 6:00 to start the machine;
5. 机器启动运行后请仔细关注电压400V,频率50HZ,转速1500转,运行10分钟待水温上升至60℃时,将转换开关由6点方向旋转至9点方向即为待机运行状态,5分钟后机器会自动停机;
5. After the machine is started, please pay attention to the voltage of 400V, frequency of 50Hz, speed of 1500 rpm, and run for 10 minutes. When the water temperature rises to 60 ℃, turn the universal change-over switch from 6 o'clock to 9:00 o'clock, which is the standby operation mode. After 5 minutes, the machine will stop automatically;
6. 测试结束后,请回复断路器合闸状态,将转换开关由9点方向旋转至3点方向,待停电时会自动启机。
6. After the test, please return to the closing state of the circuit breaker, turn the universal transfer switch from 9:00 to 3:00, and the machine will start automatically when the power is cut off.