燃气发电机组突然不转的原因是什么?

返回 2020.03.02 来源:http://www.huannengpower.com 0
   这时,如果燃气发电机组突然不转,就会给工作带来很大的麻烦,尤其是生产单位,延误了工作就会延误交货期。这是制造商的损失。因此,天然气发电机组突然不转,必须提出一个合理有效的解决方案。一般来说,天然气发电机组突然不转是由于以下两个方面的原因:

  At this time, if the gas generator unit does not run suddenly, it will bring great trouble to the work, especially to the production unit. If the work is delayed, the delivery time will be delayed. This is the loss of the manufacturer. Therefore, a reasonable and effective solution must be put forward if the natural gas generator unit does not run suddenly. Generally speaking, the sudden non operation of natural gas generator unit is due to the following two reasons:

  1. 经过长时间的停车后,发电机无法启动。

  1. After a long shutdown, the generator cannot be started.

  2. 天然气发电机组在运行过程中因噪声异常突然熄火,重新启动时发电机无法转动。

  2. During the operation of the natural gas generator unit, due to the abnormal noise, the generator suddenly stalls and cannot rotate when it is restarted.

  如果以上两个方面的问题,我们应该考虑的原因是什么。

  If there are two problems above, what are the reasons we should consider.

  1. 摘要燃气发电机组在运行过程中突然出现异常噪声,导致发电机的外燃。主要原因是:碰撞、气缸粘滞、曲轴或连杆断裂,导致发电机无法启动。如果进、出气阀被堵塞,进、出气阀无法抽走,或活塞内有异物,发电机启动时不转。

  1. During the operation of gas generator unit, abnormal noise suddenly appears, which leads to the external combustion of generator. The main causes are: collision, sticking cylinder, broken crankshaft or connecting rod, which makes the generator unable to start. If the air inlet and outlet valves are blocked, the air inlet and outlet valves cannot be removed, or there is foreign matter in the piston, the generator will not run when starting.

  2. 如果天然气发电机组长时间不使用,二次使用也会失败:如电池极接触不良,启动线不接或电池线断了,线不接;蓄电池容量不足,不能带动起动器转动等。或者起跑线本身断裂;起动机的磁性开关有故障;起动机的齿轮未能与发电机飞轮的齿圈啮合,导致无法启动。

  2. If the natural gas generator is not used for a long time, the secondary use will also fail: for example, the battery pole is in poor contact, the starting line is not connected or the battery line is broken, the line is not connected; the battery capacity is insufficient to drive the starter to rotate, etc. Or the starting line itself is broken; the magnetic switch of the starter is faulty; the gear of the starter fails to mesh with the ring gear of the flywheel of the generator, resulting in the failure to start.

  如果天然气发电机突然停止运行,我们可以通过两种方式进行调整:

  If the natural gas generator stops suddenly, we can adjust it in two ways:

  一、对极柱、电瓶线、起动机磁开关、起动线进行保养。

  1、 Maintain pole, battery line, starter magnetic switch and starting line.

  其次,应将发电机曲轴箱、阀盖、缸盖分别拆下并检查以上可能出现的故障区域。

  Secondly, remove the crankcase, valve cover and cylinder head of the generator and check the above possible fault areas.

 

  以上是燃气发电机组厂家为大家介绍的相关内容,想要了解更多内容,欢迎访问网站:http://www.huannengpower.comThe above is the relevant content introduced by the gas generator unit manufacturer. For more information, please visit the website: http://www.huannengpower.com

上一条:

下一条:沼气发电机组的优点是什么?

新闻搜索
济南济柴环能燃气发电设备有限公司
  • 服务热线

    0531-62325028
    0531-69951266

燃气发电机组突然不转的原因是什么?

   这时,如果燃气发电机组突然不转,就会给工作带来很大的麻烦,尤其是生产单位,延误了工作就会延误交货期。这是制造商的损失。因此,天然气发电机组突然不转,必须提出一个合理有效的解决方案。一般来说,天然气发电机组突然不转是由于以下两个方面的原因:

  At this time, if the gas generator unit does not run suddenly, it will bring great trouble to the work, especially to the production unit. If the work is delayed, the delivery time will be delayed. This is the loss of the manufacturer. Therefore, a reasonable and effective solution must be put forward if the natural gas generator unit does not run suddenly. Generally speaking, the sudden non operation of natural gas generator unit is due to the following two reasons:

  1. 经过长时间的停车后,发电机无法启动。

  1. After a long shutdown, the generator cannot be started.

  2. 天然气发电机组在运行过程中因噪声异常突然熄火,重新启动时发电机无法转动。

  2. During the operation of the natural gas generator unit, due to the abnormal noise, the generator suddenly stalls and cannot rotate when it is restarted.

  如果以上两个方面的问题,我们应该考虑的原因是什么。

  If there are two problems above, what are the reasons we should consider.

  1. 摘要燃气发电机组在运行过程中突然出现异常噪声,导致发电机的外燃。主要原因是:碰撞、气缸粘滞、曲轴或连杆断裂,导致发电机无法启动。如果进、出气阀被堵塞,进、出气阀无法抽走,或活塞内有异物,发电机启动时不转。

  1. During the operation of gas generator unit, abnormal noise suddenly appears, which leads to the external combustion of generator. The main causes are: collision, sticking cylinder, broken crankshaft or connecting rod, which makes the generator unable to start. If the air inlet and outlet valves are blocked, the air inlet and outlet valves cannot be removed, or there is foreign matter in the piston, the generator will not run when starting.

  2. 如果天然气发电机组长时间不使用,二次使用也会失败:如电池极接触不良,启动线不接或电池线断了,线不接;蓄电池容量不足,不能带动起动器转动等。或者起跑线本身断裂;起动机的磁性开关有故障;起动机的齿轮未能与发电机飞轮的齿圈啮合,导致无法启动。

  2. If the natural gas generator is not used for a long time, the secondary use will also fail: for example, the battery pole is in poor contact, the starting line is not connected or the battery line is broken, the line is not connected; the battery capacity is insufficient to drive the starter to rotate, etc. Or the starting line itself is broken; the magnetic switch of the starter is faulty; the gear of the starter fails to mesh with the ring gear of the flywheel of the generator, resulting in the failure to start.

  如果天然气发电机突然停止运行,我们可以通过两种方式进行调整:

  If the natural gas generator stops suddenly, we can adjust it in two ways:

  一、对极柱、电瓶线、起动机磁开关、起动线进行保养。

  1、 Maintain pole, battery line, starter magnetic switch and starting line.

  其次,应将发电机曲轴箱、阀盖、缸盖分别拆下并检查以上可能出现的故障区域。

  Secondly, remove the crankcase, valve cover and cylinder head of the generator and check the above possible fault areas.

 